One Excellent Job Leads To Another

Workshop 60 Infrastructure Modernization

media
Workshop 60 Infrastructure Modernization

Critical Upgrades Performed

1. Insulated Rolling Door Replacement

Specifications
  • 6m x 4m motorized door
  • R-12 insulation rating
  • Impact-resistant aluminum construction
Benefits
  • 40% reduction in HVAC energy loss
  • Secure against sandstorms

2. Genie 6S-2032 Lift Repair

Components Restored
  • Hydraulic system overhaul
  • Control panel replacement
  • Structural reinforcement
Performance Gains
  • Restored 2-ton lifting capacity
  • Enhanced safety interlocks

Execution Highlights

  • Minimized Downtime: Completed during routine maintenance window
  • Custom Solutions: Door track alignment for desert thermal expansion, Genie load-testing to 110% capacity
  • Safety: Zero lost-time incidents

Technical Specifications

System Standards & Warranty

System Standard Warranty
Rolling Door ANSI/DASMA 115 5 years
Genie Lift ASME B30.20 3 years

Operational Impact

  • Productivity: Reduced equipment transfer time by 35%
  • Reliability: Zero door malfunctions since installation
  • Safety: New Genie safety systems reduced near-misses by 100%

Information About the Project

Location Workshop 60
End-User Egyptian Air Defense
Award Date May 2020
Contract W912ER-20-F-0073 (Task Order #17)